• Ultra Short Range 3D Scanner Surphaser® Model 75HSX

    Ideal for high-precision scanning at short distances, Surphaser 75 gives users the ability to quickly collect high-accuracy, high-resolution data starting as close as 25cm (<1ft).

    Photo courtesy of MD3D UK

  • 3D Scanner Surphaser® 100HSX

    Sub-millimeter accuracy scanners with a scan rate of up to 1 million points per second and a scan range between 1m and 50m. Photo courtesy of Mimic Studios
  • 3D Scanner Surphaser® 410HSX

    Submillimeter range noise on distances up to 100 m, scanning speed up to 832,000 points per second, easy portability, known Surphaser accuracy and reliability. Photo courtesy of GEOS3D, Austria

Hemispherical 3D Scanners Surphaser®

Got Questions?

We’ve got answers
SurphaserFamily_19551-a-pqpm7ij3z1d7a8uz52iceflbgq33pfg731v4k6aps4 (1)

Surphaser® Configuration Options:

Configuration75HSX Class 3R80HSX4 Class 1100HSX SR Class 3R100HSX IR4 Class 3R10HSX Class 1410HSX4 Class 1
Mode (software selectable)
HQ

208,000 pps

HQ

208,000 pps

HP

832,000 pps

HQ

208,000 pps

HQ

208,000 pps

HS

208,000 pps

HQ

208,000 pps

HS

208,000 pps

HQ

208,000 pps

HS

208,000 pps

HP

832,000p ps

Recommended Work
Range (m)
0.25-2.50.25-70.25-71-71-351-501-501-1100.4-700.4-700.4-70
Ambiguity Range (m)90180180909090180180180360180
Angular Uncertainty1,3
(arc sec)
2525251515152525252525
Range Noise1,2, mm;
90% reflectivity
0.025@
0.3m-2m
0.045mm@
0.3m-4m
0.11mm@
0.3m-4m
0.024@
4m
0.07@
10m
0.16@
10m
0.12@
15m
0.25@
15m
0.06@
0.4m-30m
0.09@
0.4m-30m
0.15@
0.4m-30m
Range Noise1,2, mm;
10% reflectivity
0.07@
0.5m-1.8m
0.14mm@
0.3m-4m
0.30mm@
0.3m-4m
0.088@
4m
0.41@
10m
0.3@
10m
0.3@
15m
0.7@
15m
0.15@
0.4m-15m
0.15@
0.4m-15m
0.3@
1m-15m
Range Uncertainty,mm<0.15@
1.5m
<0.25@
1.5m
<0.35
@1.5m
<0.3@
3m
<0.35@
5m
<0.7@
15m
<0.7@
15m
<0.9@
15m
<0.7@
15m
<0.9@
15m
<0.9@
15m
1 All noise and uncertainty figures are for 1 sigma level
2 Range noise — local (short term) range variation, Lambertian surface
3  Evaluated with contrast target best fit at data rate of 208,000/832,000 points per sec respectively
4HQ, HS and HP are software selectable options based on the same hardware model 100HSX IR (HQ and HS only), models 80HSX, 400HSX and 410HSX (HQ, HS and HP).
System Parameters may be changed without notice; parameters are rated independently

Surphaser® Configuration Options:

Configuration 75HSX Class 3R 80HSX4 Class 1 100HSX SR Class 3R 100HSX IR4 Class 3R 400HSX4 Class 1 410HSX4 Class 1
Mode (software selectable)
HQ
HQ
208,000 pps
HP
832,000 pps
HQ
HQ
HS
HQ
208,000 pps
HS
208,000 pps
HP
832,000 pps
HQ
208,000 pps
HS
208,000 pps
HP
832,000p ps
Recommended Work Range (m) 0.25-2.5 0.25-7 0.25-7 1-7 1-35 1-50 1-140 1-250 1-110 0.4-70 0.4-70 0.4-70
Ambiguity Range (m) 90 180 180 90 90 90 180 360 180 180 360 180
Angular Uncertainty1,3 (arc sec) 25 25 25 15 15 15 25 25 25 25 25 25
Range Noise1,2, mm; 90% reflectivity 0.025@ 0.3m-2m 0.045mm @ 0.3m4m 0.11mm @ 0.3m4m 0.024@ 4m 0.07@ 10m 0.16@ 10m 0.07@ 1-30m 0.1@ 1-30m 0.2@ 1-30m 0.06@0. 4m-30m 0.09@0. 4m-30m 0.15@0.4 m-30m
Range Noise1,2, mm; 10% reflectivity 0.07@ 0.5m-1.8m 0.14mm @ 0.3m4m 0.30mm @ 0.3m4m 0.088 @4m 0.41@ 10m 0.3@ 10m 0.15@ 1-15m 0.2@ 1-15m 0.4@ 1-15m 0.15@0. 4m-15m 0.15@0. 4m-15m 0.3@1m15m
Range Uncertainty3sup> ,mm <0.15@ 1.5m <0.25 @1.5m <0.25 @1.5m <0.3@ 3m <0.35@ 5m <0.7@ 15m <0.7@ 15m <0.9@ 15m <0.9@ 15m <0.7@15 m <0.9@15 m <0.9@15 m
1 All noise and uncertainty figures are for 1 sigma level
2 Range noise — local (short term) range variation, Lambertian surface
3  Evaluated with contrast target best fit at data rate of 208,000/832,000 points per sec respectively
4HQ, HS and HP are software selectable options based on the same hardware model 100HSX IR (HQ and HS only), models 80HSX, 400HSX and 410HSX (HQ, HS and HP).
System Parameters may be changed without notice; parameters are rated independently

Applications